Find a feature. Open its criteria. Go straight to the source. For ICP, brain oxygen and the other monitored signals, see the multimodal simulator reference.

81 terms
2 entries · Epileptiform discharges
Epileptiform discharges

Centrotemporal spikes and the SeLECTS EEG pattern

Centrotemporal epileptiform discharges may show a transverse dipole and sleep activation; the SeLECTS syndrome requires appropriate clinical context.

Criteria & assessment

  • Review central/temporal negativity and frontal positivity in suitable montages.
  • Assess morphology, background, sleep activation and independent or synchronous bilateral discharges.

Associated gallery EEGs

These earlier examples show the centrotemporal field and sleep activation; they predate the revised peak and variability profile.

3 related papers →
Generation & measurement notes
  • Edition-7 profile 4 retains profile 3's sharper central negative peak, positive lobes, slow wave and transverse dipole. Published descriptions include rounded or broad forms; the sharper teaching contour is a provisional visual-review adjustment. Variation remains coherent within the source family; explicit profiles 1–3 remain reproducible. This is a teaching template, not a population model.
  • When the SeLECTS target voltage is omitted, profile 4 uses 180 µV, including on a default child background. Explicit profile 3 retains its 80 µV default; explicitly authored voltages are unchanged. This reviewer-selected teaching preset is not a published typical clinical amplitude.

Editorial draft · clinical review pending

Open permanent page →
Epileptiform discharges

Short IED clusters and rhythmic runs

Clustering and rhythmic runs describe temporal organization of discharges; they do not independently determine a seizure or periodic-discharge classification.

Criteria & assessment

  • Inspect interdischarge intervals, morphology, frequency, evolution, duration and the surrounding EEG.
  • Irregular clusters have variable gaps; rhythmic runs may require periodic-discharge or spike-and-wave terminology after contextual review.

Associated gallery EEGs

No approved gallery example is currently available for this feature.

No approved gallery example of the new short-run organization is available. Existing periodic-discharge or BIRDs examples are not substitutes.

Generation & measurement notes
  • Edition-7 profiles 2–4 use the same variable renewal gaps for irregular clusters and the same timing feasibility checks. Authored cadence is a driving ceiling; pauses lower observed frequency. Explicit rhythmic runs remain available and require contextual PD/SW review.
  • Requested runs are opt-in, shorter than 10 seconds and separated by at least 10 seconds in this conservative generator family. These are engineering guards, not diagnostic definitions.
  • Runs replace this source's baseline discharges in reserved run and separation windows. Baseline rate applies outside; other IED sources are preserved.