Stimulus state, evolution, fluctuation, and static modifiers
Stimulus modifiers describe reproducible response to alerting stimulation; temporal modifiers describe frequency, morphology, or location change.
Criteria & assessment
- stimulus state
- SI
- Reproducibly brought about or exacerbated by alerting stimulus in a less-stimulated state, with or without clinical alerting; may also occur spontaneously.
- ST
- Reproducibly terminated or attenuated by alerting stimulus in a less-stimulated state, with or without clinical alerting; may also self-terminate.
- spontaneous
- Never clearly induced, exacerbated, improved, or terminated by stimulation.
- unknown
- Unclear or untested.
- stimulus type required
- auditory
- light tactile
- patient care/other nonnoxious
- noxious
- evolving
- minimum
- At least 2 unequivocal sequential changes in the same category.
- frequency
- Two consecutive changes in one direction, each at least 0.5 Hz; each frequency persists at least 3 cycles.
- morphology
- Two consecutive novel morphologies; each morphology, including transition forms, persists at least 3 cycles.
- location
- Sequential spread into or out of at least 2 standard 10-20 electrode locations; involvement of each additional electrode persists at least 3 cycles.
- interstep gap
- Reach criteria without the changing feature remaining unchanged for 5 or more continuous minutes.
- amplitude
- Voltage/amplitude change alone is neither evolution nor a new morphology.
- fluctuating
- minimum
- At least 3 changes, no more than 1 minute apart, not qualifying as evolution.
- frequency
- Each change at least 0.5 Hz; each frequency persists at least 3 cycles.
- morphology
- Each morphology persists at least 3 cycles.
- location
- Each change at least 1 standard interelectrode distance; each location persists at least 3 cycles.
- amplitude
- Voltage/amplitude change alone is not fluctuation.
- static
- Neither evolving nor fluctuating.
- additional reporting
- If evolving or fluctuating in frequency, specify minimum and maximum frequency. For nongeneralized patterns specify spread as none, unilateral, or bilateral.
Associated gallery EEGs
Source · 2021ACNS critical-care EEG terminology · PDF p. 14 ↗
Evolution · EEG 16 · PDF p. 17 ↗Fluctuation · EEG 17 · PDF p. 18 ↗Related literature
Published papers on this feature. Each was checked against the feature by independent automated reviewers before being listed. The reviewers worked from findings extracted from the paper; a clinician has not read each one.
- Shugan A. Waveform Window #57: Cefepime Neurotoxicity in EEG. Neurodiagn J. 2024;64(3):156-165.
- Gaspard N, Hirsch LJ. Pitfalls in ictal EEG interpretation: critical care and intracranial recordings. Neurology. 2013;80(1 Suppl 1):S26-42.
- Chong DJ, Hirsch LJ. Which EEG patterns warrant treatment in the critically ill? Reviewing the evidence for treatment of periodic epileptiform discharges and related patterns. J Clin Neurophysiol. 2005;22(2):79-91.
- Bosque-Varela P, Jannone-Pedro N, Machegger L, et al. Rethinking the electrographical boundaries of status epilepticus: controversies and paradoxes of the ictal-interictal continuum. Front Neurol. 2026;17:1802653.
- Bitar R, Khan UM, Rosenthal ES. Utility and rationale for continuous EEG monitoring: a primer for the general intensivist. Crit Care. 2024;28(1):244.
- Hwang J, Cho SM, Ritzl EK. Recent applications of quantitative electroencephalography in adult intensive care units: a comprehensive review. J Neurol. 2022;269(12):6290-6309.
- Kapinos G, Trinka E, Kaplan PW. Multimodal Approach to Decision to Treat Critically Ill Patients With Periodic or Rhythmic Patterns Using an Ictal-Interictal Continuum Spectral Severity Score. J Clin Neurophysiol. 2018;35(4):314-324.
- Bauer G, Trinka E, Kaplan PW. EEG patterns in hypoxic encephalopathies (post-cardiac arrest syndrome): fluctuations, transitions, and reactions. J Clin Neurophysiol. 2013;30(5):477-89.
- Claassen J, Jetté N, Chum F, et al. Electrographic seizures and periodic discharges after intracerebral hemorrhage. Neurology. 2007;69(13):1356-65.
Generation & measurement notes
- Use an event sequence rather than a single classifier score so cycle persistence, direction, and interstep gap can be audited.