Skip to main content
← qEEG

Amplitude-integrated EEG

A compressed amplitude display whose envelope depends on filtering, derivation and processing.

Criteria & assessment

  • Inspect upper/lower margins and raw EEG at matching times.

Associated gallery EEGs

Related literature

Published papers on this feature. Each was checked against the feature by independent automated reviewers before being listed. The reviewers worked from findings extracted from the paper; a clinician has not read each one.

  1. Thoresen M, Hellström-Westas L, Liu X, et al. Effect of hypothermia on amplitude-integrated electroencephalogram in infants with asphyxia. Pediatrics. 2010;126(1):e131-9.
  2. Lust C, Vesoulis Z, Zempel J, et al. An Amplitude-Integrated EEG Evaluation of Neonatal Opioid Withdrawal Syndrome. Am J Perinatol. 2024;41(S 01):e290-e297.
  3. Lena K. Hellström-Westas, Ingmar Rosén, Linda S. de Vries, et al. Amplitude-integrated EEG Classification and Interpretation in Preterm and Term Infants. NeoReviews. 2006;7(2):e76-e87.
  4. al Naqeeb N, Edwards AD, Cowan FM, et al. Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography. Pediatrics. 1999;103(6 Pt 1):1263-71.
  5. El-Dib M, Chang T, Tsuchida TN, et al. Amplitude-integrated electroencephalography in neonates. Pediatr Neurol. 2009;41(5):315-26.
  6. Pisani F, Spagnoli C. Monitoring of newborns at high risk for brain injury. Ital J Pediatr. 2016;42(1):48.
  7. van Rooij LG, Toet MC, Osredkar D, et al. Recovery of amplitude integrated electroencephalographic background patterns within 24 hours of perinatal asphyxia. Arch Dis Child Fetal Neonatal Ed. 2005;90(3):F245-51.
  8. Lamblin MD, Walls Esquivel E, André M. The electroencephalogram of the full-term newborn: review of normal features and hypoxic-ischemic encephalopathy patterns. Neurophysiol Clin. 2013;43(5-6):267-87.
All 19 papers
  1. Shellhaas RA, Gallagher PR, Clancy RR. Assessment of neonatal electroencephalography (EEG) background by conventional and two amplitude-integrated EEG classification systems. J Pediatr. 2008;153(3):369-74.
  2. Kumar Krishnegowda V, Ramaswamy VV, Bandiya P, et al. Early Electroencephalography and Amplitude-Integrated Electroencephalography for the Prediction of Neurodevelopmental Outcomes in Neonates with Hypoxic Ischemic Encephalopathy: A Systematic Review and Diagnostic Test Accuracy Meta-Analysis. Neonatology. 2026;123(1):84-109.
  3. Montazeri S, Gonzalez-Tamez K, Ågren J, et al. Clinical Validation of the New EEG Trend, Brain State of the Newborn, Against aEEG Interpretation. Acta Paediatr. 2026.
  4. Chock VY, Rao A, Van Meurs KP. Optimal neuromonitoring techniques in neonates with hypoxic ischemic encephalopathy. Front Pediatr. 2023;11:1138062.
  5. Nyman J, Mikkonen K, Metsäranta M, et al. Poor aEEG background recovery after perinatal hypoxic ischemic encephalopathy predicts postneonatal epilepsy by age 4 years. Clin Neurophysiol. 2022;143:116-123.
  6. Boylan GB, Kharoshankaya L, Mathieson SR. Diagnosis of seizures and encephalopathy using conventional EEG and amplitude integrated EEG. Handb Clin Neurol. 2019;162:363-400.
  7. Awal MA, Lai MM, Azemi G, et al. EEG background features that predict outcome in term neonates with hypoxic ischaemic encephalopathy: A structured review. Clin Neurophysiol. 2016;127(1):285-296.
  8. Schreiner C, Stock K, Höck M, et al. Perinatal arterial ischemic stroke - Is amplitude integrated EEG a helpful tool for the clinician?. Early Hum Dev. 2026;221:106601.
  9. van der Steen D, Koopman AA, Oppersma E, et al. Exploring state changes/sleep-wake cycling in mechanically ventilated children using amplitude-integrated EEG. Clin Neurophysiol. 2026;190:2112328.
  10. Wusthoff CJ, Numis AL, Pressler RM, et al. The American Clinical Neurophysiology Society Guideline on Indications for Continuous Electroencephalography Monitoring in Neonates. J Clin Neurophysiol. 2025;42(1):1-11.
  11. Corlette SJ, Walker SM, Cornelissen L, et al. Changes in the Term Neonatal Electroencephalogram with General Anesthesia: A Systematic Review with Narrative Synthesis. Anesthesiology. 2024;141(4):670-680.